Uncover the lever of switching and the lever handle, address to the Section Removal and installation of a cover of the lever of switching of transfers/selector.
|
Pull a slip (1) at first in the direction of an arrow (And) and then take out in the arrow direction (In).
|
|
|
At cars with the control panel of the conditioner located over an ashtray, it is necessary to extend the panel a little previously. |
|
Turn out fastening bolts (C) and take out an ashtray (2) of the central console.
|
Take out up a dempfiruyushchy washer (1) and a damper of noise (2).
|
|
Turn out bolts of fastening of a cover (an arrow on an accompanying illustration).
|
|
Measure distance (and) between two carving fingers in a switching drive.
|
|
|
It is necessary to measure between centers fingers. |
|
The distance should be and = 85 mm. If the received value differs from specified, adjust distance (and) as follows: Weaken the screw (shooter) of fastening of a pushing bar. The pushing bar should move easily in both parties behind in a switching drive on ползуне.
|
Adjust the size (and) by shift of a pushing bar behind. Tighten a bolt of fastening of a pushing bar the moment 25Нм.
|
Weaken a bolt (the shooter on an accompanying illustration) in a switching drive. Connection pushing a bar/drive of switching should have an easy course.
|
|
Establish the switching lever: The lever should be centered below in a spherical support. The distance from a spherical support to the switching lever below from all directions should be identical.
|
|
Establish the lever vertically in the direction of movement and hold him in this situation.
|
Tighten a bolt of fastening of a bar of switching the moment 25Нм.
|
|
Tighten bolts of fastening of a cover of protection against noise by the moment 10Нм. Watch the provision of installation: The arrow on a cover specifies in the direction "forward".
|
|
The inclusion button with the fixing mechanism: Establish the button together with a cover of the lever of switching on the lever and turn a connecting element against the stop.
The inclusion button with a tightening collar: Establish the button of inclusion by a snovy collar on the lever of switching and squeeze a collar flat-nose pliers.
If necessary, establish the control unit the conditioner and an ashtray.
|